DO-160 Section 16: Every Power Input Condition Your Source Has to Generate
Aviation & 400 Hz · 3 min read · 36 cited facts
DO-160 Section 16 is not one test. It is a category system, and the first thing that determines your bench is which letter your equipment is qualified under. Get the category wrong and you will either buy a source that cannot run the clauses or spend money reaching conditions your programme never has to demonstrate.
Categories decide everything downstream
- A(CF) — 400 Hz constant frequency
- A(NF) — 360 to 650 Hz narrow variable frequency
- A(WF) — 360 to 800 Hz wide variable frequency
- A — 28 VDC supplied from a transformer-rectifier unit
- B — 14 or 28 VDC with a floating battery
- D — 270 VDC
- Z — 28 VDC from a variable-speed generator with no battery
A(CF) equipment needs a source that holds 400 Hz precisely. A(WF) equipment needs one that sweeps to 800 Hz and slews between. Those are different instruments, and the difference is not marginal.
Steady state is a matrix, not a setpoint
| Parameter | Value | Clause |
|---|---|---|
| AC normal steady state | 100 V and 122 V, 30 min per point | 16.5.1.1 |
| AC abnormal | 97 V and 134 V for 30 min; undervoltage 60 V and 10 V for 7 s | 16.5.2 |
Each of those points is held for thirty minutes, at each frequency corner for your category. The test time adds up quickly, which is why sequencing and unattended operation matter more here than raw capability.
Modulation is where basic sources fall over
| Parameter | Value | Clause |
|---|---|---|
| Voltage modulation | envelope to 5.0 V at 115 V, 1–200 Hz | 16.5.1.2 |
| Momentary interruptions | 19 profiles, 2 ms–200 ms at 0 V, plus partial sags 15/35/50/65% | 16.5.1.4 |
Surges size the instrument
| Parameter | Value | Clause |
|---|---|---|
| Normal surge | 160 V for 30 ms (A(CF)/A(NF)); sag 70 V for 30 ms | 16.5.1.5 |
| Abnormal surge | 180 V for 100 ms then 148 V for 1 s | 16.5.2 |
| DC ripple | <4 Vp-p on 28 V, <16 Vp-p on 270 V, 10 Hz–30 kHz | Ch.18 Fig 18-3/18-4 |
| Engine-start undervoltage | drop to 10 V, ramp 0.3 V/s for 35 s to 20.5 V | 16.6.1 (B/Z) |
The engine-start profile is worth dwelling on. It is a slow ramp — 0.3 V per second across 35 seconds — rather than a step. That exercises hold-up and brown-out behaviour in a way no transient does, and it needs a source that can be driven smoothly rather than stepped.
How this differs from MIL-STD-704F
Both describe an aircraft bus, and both demand a programmable source. The practical difference is shape: 704F is organised around normal, abnormal, emergency and starting states for each power type, while DO-160 is organised around equipment categories and a long list of discrete numbered conditions. A bench built for one will usually cover much of the other, but the test sequences do not transfer, and neither do the acceptance criteria.
Building a DO-160 §16 bench?
Tell us your equipment category and which conditions you have to demonstrate. We will come back with what covers them.
Talk to an engineerRelated
More on aviation & 400 hz
- 28 VDC Aircraft Bus Testing: The Second Programme Inside MIL-STD-704F5 min · 37 facts
- DO-160 Section 17: The Spike Your Section 16 Source Cannot Make3 min · 21 facts
- DO-160 vs MIL-STD-704: Where Civil and Military Aircraft Power Standards Split6 min · 67 facts
- Sizing a 400 Hz Source for Inrush: kVA Is the Last Number to Pick5 min · 33 facts