IEC 61000-4-29

IEC 61000-4-29 DC Input Immunity Testing

Revision Edition 2.0, 2026-07 (published 30 July 2026), replaces Edition 1.0:2000

A single programmable DC power supply is an accepted generator architecture (Annex A, Figure A.2) — provided it holds 0.5–50 µs voltage-change edges into 100 Ω, sinks as well as sources peak inrush current to 220 A, keeps at least 20 % steady-state current margin over the EUT, and can present a genuine high-impedance output for interruptions: disconnecting, not merely programming 0 V, so the EUT cannot back-feed the gap.

This standard turns on

  • voltage dips and interruptions on DC input ports
  • high- versus low-impedance interruption modes
  • durations in absolute seconds, not mains cycles — the DC counterpart of IEC 61000-4-11

And says nothing about

  • ripple on the DC port — IEC 61000-4-17's job
  • AC input ports — IEC 61000-4-11's job
  • transient overvoltages injected by network faults — explicitly out of scope
  • pass/fail severity selection — deliberately left to product committees

Cited limits

Every value carries the clause, table or figure it comes from.

ParameterValueClause
Voltage dip levels40 % and 70 % of UT (60 % and 30 % dips), abrupt microsecond-range transitionsClause 5 / Table 1
Short interruptions0 % UT for 0.001 / 0.003 / 0.01 / 0.03 / 0.1 / 0.3 / 1 s, in high-impedance and/or low-impedance conditionTable 2
Voltage variations85 % and 120 %, or 80 % and 120 % of UT, for 0.1 / 0.3 / 1 / 3 / 10 s; ramp times set by the product standardTable 3
Rated-voltage-range ruleif the upper limit of the EUT's rated range exceeds the lower by more than 20 %, the full procedure runs at both limitsClause 5
Generator output voltageup to 120 % of the maximum UT; a 780 V DC / 25 A generator is recommended to cover a large number of applications§6.2.1
Voltage-change edgesrise and fall 0.5–50 µs into a 100 Ω load, overshoot/undershoot < 10 % of the change§6.2.1
Peak inrush current drive50 A at 24 V, 100 A at 48 V, 220 A at 110 V, 100 A at 650 V — positive towards the EUT and negative reverse from it§6.2.2
Steady-state current margingenerator rated output current at least 120 % of the EUT's rated input current§6.2.1

Where these figures came from

Each record below backs a specific part of this page. Where a table sits behind a paywall we say so above rather than reproducing it.

Further reading