Regenerative AC electronic load.

What happened to it

No manufacturer product page exists. What remains online is resellers listing the individual wattage variants.

The substitution that goes wrong

AC loads are frequently replaced on power rating alone. Crest factor is what determines whether the load can actually absorb the waveform your DUT produces.

Specifications to match

  • AC voltage and frequency window — and whether 400 Hz is in scope, because that changes which line answers
  • Crest factor and power factor capability against your actual DUT
  • Regenerative path interconnection requirements
  • Behavior under unbalanced three-phase load

Before you swap the hardware

A replacement that matches on headline power can still fail on the details that keep an existing rack working.

  1. 01Match the AC voltage and frequency window; if the requirement includes 400 Hz, the comparison moves to the AN61(F) or the AFC.
  2. 02Verify crest factor and power factor capability against your DUT.
  3. 03Check grid-tie interconnection requirements for the regenerative path.

Where Intepro fits

The closest current equivalent is the ANRGS(F) Series Regenerative Grid Simulator, manufactured by Ainuo and supplied and integrated by Intepro. Every figure below is transcribed from its datasheet and re-checked against that document on each build.

Power range3kVA - 120kVA
Output voltage0.00~350.00V AC; -495.00~495.00V DC
Output frequency30.000~100.000Hz
Part numbersANRGS003S-350 · ANRGS005S-350 · ANRGS006S-350 · ANRGS010S-350 · ANRGS012S-350 · ANRGS015S-350 · ANRGS020S-350 · ANRGS006A-350 · +13 more

Manufactured by Ainuo. This page presents the MANUFACTURER'S full series, transcribed from Ainuo's own published tables (read from images, because Ainuo publishes specifications as pictures rather than text). It does not assert that Intepro stocks every model — confirm availability before quoting.

Where this one stops

The ANRGS(F) is a regenerative grid simulator that sources and sinks; it is not sold as an AC load and its specification is written from the source side. If your 4700 was used purely as a load and never as a source, you are paying for capability you will not use — worth saying before you quote, not after. Note also that its band is 30.000~100.000Hz, so a 400 Hz requirement belongs on the AN61(F) or the AFC instead.

Further reading

Send us the spec you have to hit

Include the model you are replacing and what it was doing. We will come back with what matches and what does not.